Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Pacing Clin Electrophysiol ; 36(8): 963-9, 2013 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-23692289

RESUMO

BACKGROUND: The Quartet quadripolar lead (St. Jude Medical Inc., St. Paul, MN, USA) offers 10 different left ventricle pacing configurations that may further influence hemodynamic parameters compared to traditional bipolar pacing configurations. The purpose of this study was to evaluate whether pacing from additional quadripolar lead vectors could enhance cardiac output (CO). METHODS: For each patient, CO was measured in "no-pacing" and in all the 10 configurations available, within 7 days of implantation of the device. Tip-ring, tip-right ventricular coil (RVC), and ring-RVC vectors were considered as traditional vectors. The seven additional configurations available in the quadripolar lead were considered as nontraditional vectors. CO was measured by ECHO. The best configuration was defined as the one presenting the highest CO measurement within configurations, which have a capture threshold <3 V and a safety margin between the capture and the phrenic nerve stimulation thresholds. RESULTS: Fifty-one standard cardiac resynchronization therapy patients were enrolled. The mean of each patient's best CO obtained with traditional vectors was higher than the baseline nonpaced CO (4.16 L/min vs 3.64 L/min). The mean of each patient's best CO, including all 10 available configurations, was also higher than the baseline nonpaced CO (4.33 L/min vs 3.64 L/min). In addition, the mean of each patient's best CO obtained with the best configuration available through a quadripolar lead was better than the mean of each patient's best CO obtained with a traditional configuration. In 53% of patients, the best CO was obtained with a nontraditional vector unique to the quadripolar lead. CONCLUSIONS: A quadripolar lead offers multiple additional pacing options to increase CO acutely compared to conventional bipolar leads.


Assuntos
Débito Cardíaco , Dispositivos de Terapia de Ressincronização Cardíaca , Eletrodos Implantados , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/prevenção & controle , Disfunção Ventricular Esquerda/diagnóstico , Disfunção Ventricular Esquerda/prevenção & controle , Adulto , Idoso , Desenho de Equipamento , Análise de Falha de Equipamento , Feminino , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Estudos Prospectivos , Resultado do Tratamento , Disfunção Ventricular Esquerda/fisiopatologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...